top of page

Wildfire Preparedness as a Business Asset: Navigating New Mexico's New Standards and Protecting Your Listings

  • Writer: Kim Clark
    Kim Clark
  • 13 hours ago
  • 5 min read

In New Mexico, wildfires are becoming increasingly frequent and intense due to a combination of climate change, persistent drought conditions, and accumulated forest fuels. The devastating 2022 fire season alone burned over 900,000 acres across our state. This rising environmental risk has led to skyrocketing homeowner insurance premiums in high-risk areas, with some traditional carriers withdrawing coverage entirely or issuing non-renewals. Furthermore, rebuilding costs have surged by 40% since 2020, making wildfire prevention a critical necessity for protecting our clients' financial futures.


To address these serious challenges, we were privileged to have Grant County Emergency Manager Scot Fuller speak at our recent membership meeting on the Wildfire Prepared program.

We would like to extend our sincere appreciation to Scot for his time, expertise, and for providing the detailed, science-based handouts that form the foundation of our community's wildfire defense strategies. This article translates those resources into a clear roadmap for REALTORS® to help clients maintain property insurability, enhance home values, and secure successful transactions.


The Legislative and Funding Landscape in New Mexico


New Mexico has taken significant legislative steps to support proactive wildfire mitigation. During the recent winter legislative session, two identical-goal bills were introduced to protect homes and support residents facing insurance challenges.


  • Senate Bill 33 officially created "Wildfire Prepared New Mexico" to establish safety retrofit standards and provide grant resources to homeowners, although it passed without immediate funding.

  • Fortunately, the Legislature funded the "New Mexico Home Strong" program with $10 million through appropriations to the Office of the Superintendent of Insurance [95]. This program provides critical retrofit grants specifically to homeowners insured under the FAIR plan—New Mexico’s insurance "of last resort".


Both programs leverage the scientific standards developed by the Insurance Institute for Business & Home Safety (IBHS), making the prestigious Wildfire Prepared Home™ designation available in New Mexico for the first time. This certification program is already active in California, Oregon, and Nevada, providing homeowners with documented proof that their property is resilient against wildfire. A Wildfire Prepared Certificate can be submitted to insurance carriers to potentially prevent coverage from being dropped or to avoid premium hikes. Properties meeting these standards may qualify for premium discounts of up to 15%. Moreover, taking proactive, early mitigation measures is highly cost-effective, reducing overall costs by up to 50% compared to emergency response.


A Wildfire Prepared Certificate can protect listings from non-renewals and secure up to 15% in insurance premium savings.

REALTOR® Cheat Sheet: The Two Levels of Wildfire Designation


As trusted advisors, REALTORS® can guide clients through the two levels of IBHS protection—Base and Plus—to prepare listings for evaluation and ensure transaction readiness.


1. Base-Level Designation: Ember Defense

Wind-driven embers are the leading cause of home ignitions, responsible for 60% to 90% of home losses in wildfires. The Base level focuses heavily on preventing ember ignition and fire spread:

  • The 0–5 Foot Noncombustible Zone (Zone 0): This is a horizontal "moat" extending 5 feet from the home's exterior walls (and outermost posts of attached decks, patios, or stairs) and vertically to the sky. All vegetation (including grass, weeds, flowers, shrubs, and overhanging tree branches) must be cleared down to bare mineral soil [5]. Combustible groundcover, such as wood or rubber mulch and pine needles, must be removed and replaced with noncombustible materials like gravel, pavers, river rock, stepping stones, or concrete.

  • Fences within 5 Feet: Combustible fencing materials (wood or vinyl) attached to or within 5 feet of the home must be replaced with noncombustible options such as metal (aluminum, chain link, steel, iron) or concrete. Traditional wood and vinyl gates are high-risk fuses that can bring fire directly to the structure.

  • Defensible Space (5 to 30 Feet - Zone 1): This "fuel reduction zone" requires cutting grass to less than 4 inches (or less than 18 inches on steep slopes) and removing all dead vegetation. Trees must be pruned up to a minimum of 6 feet from the ground (or 1/3 of their height if under 18 feet). Adjacent tree canopies must have at least 10 feet of horizontal clearance from each other and from chimneys. Clustered shrubs must not exceed 10 feet in combined width, must have horizontal spacing twice the height of the tallest plant, and cannot be located under tree canopies. Firewood piles must be stored at least 30 feet away from the home.


  • Key Building Features (Base):

    • Roof: Must have a Class A fire-rated roof covering (e.g., asphalt fiberglass shingles, concrete/clay tile, slate, or metal) kept entirely clear of vegetative debris [20, 56]. Gaps in barrel tiles or corrugated metal must be sealed with noncombustible bird stops to block ember intrusion.

    • Gutters and Vents: Rain gutters and downspouts must be noncombustible (metal) and clear of leaves and needles. Vents (roof, attic, gable, soffit, crawl space, and foundation) must be flame- and ember-resistant or covered with 1/8-inch or finer corrosion-resistant metal mesh screen. Forced exhaust vents (dryer/vacuum) must have functional louvers or flaps, but metal mesh should not be installed on dryer vents as it traps lint.

    • 6-Inch Siding Clearance: Exterior walls must feature at least 6 vertical inches of noncombustible siding (such as exposed concrete foundation, brick, stone, stucco, or metal flashing) at ground level and above any attached deck or patio.

    • Decks: Underdeck storage of combustible items (firewood, tools, equipment) is prohibited. Groundcover underneath elevated decks must be entirely noncombustible hardscape (bare soil, gravel, pavers, concrete) with all vegetation removed. Combustible deck posts and support walls must have at least 6 inches of noncombustible material at their base [30]. Elevated decks 4 feet or less from the ground must be enclosed with 1/8-inch corrosion-resistant metal mesh to prevent debris and embers from accumulating underneath.


2. Plus-Level Designation: Radiant Heat and Flame Defense

The Plus Designation builds upon the Base requirements and is typically achieved through new construction or extensive exterior renovations to defend against radiant heat and direct flame contact:

  • Enclosed Eaves: The exposed underside of eaves must be enclosed or protected using noncombustible soffit materials, such as fiber-cement, stucco, or 2-inch nominal lumber, with any soffit vents covered in 1/8-inch metal mesh.

  • Skylights: Plastic dome skylights must be replaced with flat, multi-paned, tempered glass skylights, with operable units protected by 1/8-inch metal mesh.

  • Gutters and Vents: Noncombustible gutters must be covered with noncombustible gutter guards or metal leaf guards. Dryer and forced exhaust vents must be made of metal or other noncombustible materials.

  • Decks: Decks and patios must either be built entirely of noncombustible materials (Option 1) or retrofitted (Option 2) to include a 0–5 foot noncombustible perimeter, solid noncombustible walking surfaces, noncombustible railings within the first 5 feet of the home, and solid noncombustible stair treads and enclosed risers.

  • Siding: All exterior wall coverings (siding) must be made of noncombustible material, such as brick, concrete, fiber-cement, masonry veneer, metal, or stucco. Combustible siding materials—including vinyl, wood lap/shake, and engineered wood—are strictly prohibited, even if treated with fire-retardant coatings.

  • Windows & Doors: All exterior windows must have at least two panes of tempered glass (with visible corner etching on

  • both panes) or glass blocks. Exterior doors must be made of noncombustible material or solid-core wood at least 1¾ inches thick, with a noncombustible threshold.

  • Detached Structures and Fencing: All detached accessory structures larger than 15 square feet (sheds, pergolas, playsets, garages) must be removed or relocated to be at least 30 feet away from the home. Back-to-back parallel combustible fencing closer than 5 feet apart within 30 feet of the home must be modified or replaced.


By integrating these scientific standards into your listing preparation and buyer consultations, you can help New Mexico homeowners defend their assets, lower their insurance costs, and keep properties safe, compliant, and highly competitive in today's real estate market.